Menu
Go back

New Amana Goodman Gas Furnace Line-Up Announced

New Amana Goodman Gas Furnace Line-Up Announced

by HVAC Distributors

We are pleased to announce that effective this fall, Amana/Goodman will be introducing a revised 90%+ Gas Furnace line-up. The new line-up has higher efficiency and greater installation flexibility (think smaller & 3-position installation). Read more for the full details!

  • New modulating ECM 97% model
    • AMVM97 – Replaces AMVM96
  • New 2 stage variable speed ECM 96% model
    • AMVC96 – Replaces AMVC95
  • New single stage multi speed 96% model
    • AMSS96 – Replaces AMH95
    • GMSS96 – Replaces GMH95
    • ACSS96 – Replaces ACSH96
    • GCSS96 – Replaces GCH95
  • New 2 stage multi speed ECM 96% model
    • AMEC96 – Replaces AMEH96
    • GMEC96 – Replaces GME95
  • New single stage multi speed 92% model
    • AMSS92 – Replaces AKSS92
    • GMSS92 – Replaces GKS9
    • ACSS92 – New Conterflow/Horizontal Left-Right
    • GCSS92 – New Conterflow/Horizontal Left-Right
  • Reduced cabinet height from 40” to 34.5” = Easier installs in height restricted areas
  • Reduced width = Less space required and smaller evap coils
    • 80,000 BTU’s in 17.5” wide cabinet
    • 100,000 BTU’s in 21” wide cabinet
  • All families now 3 position installation = More installation flexibility
    • Up/horz left-right
    • Down/horz left-right
  • Now up to 97% AFUE! = More energy savings for your customer
    • AMVM97
    • ACVM97
    • GMVM97
    • GCVM97
  • NEW 90% heat exchanger = Better efficiencies and even more dependable
    • Firing rate 20,000 BTU per burner
    • Rear header changed from Aluminum to Stainless Steel
    • 1 pc tubular design with optimized combustion air velocity
  • No joining of duel diameter tubes
    • Secondary heat exchanger from ½” to 3/8” diameter tubes
  • Internal trap plumbed for upflow = No field installation
  • Improved access to flame sensor and igniter = Easier to service
  • Thumb screws on access doors = Easy on and off access, no more screws to strip
  • Single screw size for simplified service = less tools required to service unit
  • Vertical gas valve for easy field connections = Faster/cleaner installs
  • Door sight glass aligns with control board LED = Easy service diagnostics
  • Capacitor mounted on front face of control board = More convenient location for easy access
  • Additional inlet air options = Installation flexibility
  • Silicon nitride igniter on all models = Improved reliability
  • “D” shaped blower hub = Guarantees set screw alignment
  • Pan head screws on wrapper sides = Smooth sides to minimize scratching door frames
  • Embossed single piece wrapper = Added cabinet strength and reduced air leakage
  • Reduced sharp edges & corners on sheet metal = Safer installation
  • Raised wire penetration area = Prevents condensation from running down wires to controls
  • Improved burner bracket design = Burner alignment critical to combustion
  • Eliminated blower insulation notches = Improved cabinet insulation
  • No horizontal pressure switch required for horizontal applications (AMSS92/GMSS92)

Amana Goodman Gas Furnace Line-Up